Protection
Residual
current monitoring unit Integrated
Anti
-islanding protection Integrated
DC
switch Integrated (Optional)
AC
over current protection Integrated
Insulation
monitoring Integrated
Grid
regulation
VDE-AR-N 4105, AS4777.2&.3, RD1699,
VDE0126-1-1, EN50438 G83/G59, PEA, MEA, NRS
Safety
IEC62109-1&-2, AS3100
EMC
EN61000-6-1, EN61000-6-2, EN61000-6-3,
EN61000-6-4, EN61000-3-11, EN61000-3-12
General Data
Dimensions
(WxHxD) 347*432*145mm
Weight
(kg) 14
Mounting
Wall Bracket
Ambient
temperature range -25~60
(Over 45
Derating)
Relative
humidity 0~95%
Max
. operating altitude 4000m (Over 3000m Derating)
Protection
degree IP65
Topology
Transformerless
Night
power consumption(W) <1
Cooling
Natural Convection
Noise
emision(dB) <25
Display
LCD
Communication
RS485/WiFi
Standard
warranty(years) 5/10/15/20/25 (Optional)
3.1 Technical Data DNS Series

Other manuals for Goodwe NS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe NS Series and is the answer not in the manual?

Goodwe NS Series Specifications

General IconGeneral
Protection DegreeIP65
Number of MPP Trackers2
CoolingNatural Convection
Power Range3kW to 6kW
MPPTDual MPPT
CommunicationWiFi
MPPT Voltage Range120-500V
Nominal AC Output Power3000W to 6000W
Max. AC Output Power3.3kW, 4kW, 4.6kW, 5.5kW, 6.6kW
Nominal Output Voltage230V
Operating Temperature Range-25 ~ +60 °C
Output Power3000W to 6000W
MPPT Range120-500V
Output Voltage230V
Frequency50/60 Hz