49
MDE-Radio-Timing-GTC-3080V2.3
☛ When programming a wrong date or time (e.g. 30 FEVR), the menu is
exited done without modifying date and time of the time base.
☛ In synchronization input mode, the time setting is automatic upon
reception of two successives coherent time values.
5.2. STARTING UP THE TIME PULSE DISTRIBUTION
☛ The receiver clocks connected to the relevant circuit must be preset all
at the same time.
► Press the “menu” key repeatly
until it shows next menu:
► Conrm by pressing «ENTER»:
This screen appears and the indi-
cation «NO» ashes.
► Using the «+» or «-» button, diplay
YES and conrm by «ENTER» to
activate the output screen: the
tens of hour is now ashing.
► Using the “+”, “-“ and “ENTER” buttons, set the time indicated by the clocks connected
to the circuit:
► Tens of hour
► Units of hour
► Tens of minute
► Units of minute
► Half-minute 00 or 30 seconds in the case of a half-minute circuit.
► After that, press “ENTER”, to validate the time and the display will go back automati-
cally to the basic screen.
SETTING
PULSES OUTPUT
IMP: 30s Sr 10:10:00
PULSES OUTPUT
ACTIVATION: NO
IMP: 30s Sr 10:10:00
PULSES OUTPUT
ACTIVATION: NO
TIME TO AJUST
IMP: 30s Sr 10:10:00
ENGLISH