EasyManua.ls Logo

Gossen MetraWatt PROFITEST MASTER Series - Technical Data

Gossen MetraWatt PROFITEST MASTER Series
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Gossen Metrawatt GmbH
5.5 Technical Data
Nominal Ranges of Use
Voltage U
N
120 V (108 V 132 V)
230 V (196 V 253 V)
400 V (340 V 440 V)
Frequency f
N
16⅔ Hz
(15.4 V 18 Hz)
50 Hz (49.5 V 50.5 Hz)
60 Hz (59.4 V 60.6 Hz)
200 Hz (190 V 210 Hz)
400 Hz (380 V 420 Hz)
Overall voltage range
65 V 550 V
Overall frequency range 15.4 Hz 420 Hz
Line voltage Sinusoidal
Temperature range 0 C +40C
Battery voltage 8 V 12 V
Supply impedance angle Corresponds to cos =1 0.95
Probe resistance
<50k
Reference Conditions
Line voltage 230 V 0.1%
Line frequency 50 Hz 0.1%
Measured qty. frequency
45 Hz 65 Hz
Measured qty. waveform
Sine (deviation between effective and
rectified value 0.1%)
Supply impedance angle cos =1
Probe resistance 10
Supply voltage 12 V 0.5 V
Ambient temperature + 23 C 2 K
Relative humidity 40% 60%
Finger contact For testing potential difference
to ground potential
Standing surface
insulation Purely ohmic
Power Supply
Batteries 8 each AA 1.5 V
We recommend exclusive use of the
included rechargeable battery pack
(2000 mAh, Z502H).
Number of measurements (standard setup with illumination)
– For R
INS
1 measurement – 25 s pause:
approx. 1100 measurements
– For R
LO
Auto polarity reversal / 1 
(1 measuring cycle) – 25 s pause:
approx. 1000 (Z502O) measurements
Battery test Symbolic display of rechargeable
battery voltage
Battery-saving circuit Display illumination can be switched off.
The test instrument is switched off
automatically after the last key opera-
tion. The user can select the desired
on-time.
Safety shutdown If supply voltage is too low, the instru-
ment is switched off, or cannot be
switched on.
Recharging socket Inserted rechargeable batteries can be
recharged directly by connecting a
charger to the recharging socket:
Z502R charger
Charging time Z502R charger: approx. 2 hours *
* Maximum charging time with fully depleted batteries.
A timer in the charger limits charging time to no more than 4 hours.
Overload Capacity
R
ISO
1200 V continuous
U
L-PE
, U
L-N
600 V continuous
RCD, R
E
, R
F
440 V continuous
Z
L-PE
, Z
L-N
550 V (Limits the number of measure-
ments and pause duration. If overload
occurs, the instrument is switched off
by means of a thermostatic switch.)
R
LO
Electronic protection prevents switching
on if interference voltage is present.
Protection with
fine-wire fuses FF 3.15 A 10 s,
Fuses blow at > 5 A
Electrical Safety
Protection class II
Nominal voltage 230/400 V (300/500 V)
Test voltage 3.7 kV, 50 Hz
Measuring category CAT III 600 V or CAT IV 300 V
Pollution degree 2
Fuses
L and N terminals 1 G fuse-link ea.
FF 3.15/500G 6.3 × 32 mm
Electromagnetic Compatibility (EMC)
Product standard EN 61326-1
Ambient Conditions
Accuracy 0 … + 40 C
Operation 5 … + 50 C
Storage 20 … + 60 C (without batteries)
Relative humidity
Max. 75%, no condensation allowed
Elevation Max. 2000 m
Mechanical Design
Display Multiple display with dot matrix,
128 × 128 pixels
Dimensions W × L × H = 260 × 330 × 90 mm
Weight Approx. 2.7 kg with batteries
Protection Housing: IP 40, test probe: IP 20
per EN 60529
Data Interfaces
Type USB for PC connection
Type RS 232 for barcode and RFID readers
Type Bluetooth
®
(PROFITEST MTECH+/PROFITEST MXTRA only)
For PC connection and option for connecting a
Bluetooth® keyboard (Bluetooth® Classic)
Frequency range: 2400 … 2483.5 MHz
Transmission intensity: max. + 3 dBm
BAT
Interference
emission
Class
EN 55022 A
Interference
immunity
Test value Feature
EN 61000-4-2 Contact/atmos. – 4 kV/8 kV
EN 61000-4-3 10 V/m
EN 61000-4-4 Mains connection – 2 kV
EN 61000-4-5 Mains connection – 1 kV
EN 61000-4-6 Mains connection – 3 V
EN 61000-4-11 0.5 periods / 100%

Table of Contents