s-LOCK - In a situation where a digital input is outside the lock range of the s-lock pll, it can be helpful to
disable the s-lock circuit. This parameter allows the s-lock to be independently disabled for each digital
input. Available options are enabled and disabled.
DEMPHASIS  The DAC de-emphasis lter can be congured independently for each digital input. Avail-
able options are: o, on and auto.
When o is selected, no de-emphasis ltering is applied. When on, the de-emphasis lter is engaged
for that input. The auto setting uses the de-emphasis bit in the digital audio stream to control the
de-emphasis lter. Auto de-emphasis is only available on the S/PDIF, TOSLINK, and AES3 inputs. When
de-emphasis is on, it is indicated in the top row of the DAC display.
S/MUX  The ADAT input supports 88.2/96kHz sample rate S/MUX decoding. When enabled, the available
channels switch from 1-8 to 1-4. Available options are o, on and auto. The auto setting uses the S/MUX
bit in the ADAT audio stream to control the s/mux decoding. When S/MUX is on, it is indicated in the top
row of the DAC display.
Available setup parameters for each input. Default values are in parenthesis.
UNBALANCED input name (unbalanced) level oset (0dB) meter output (enabled) input source (line)
BALANCED input name (balanced) level oset (0dB) meter output (enabled)
CUE input name (cue) level oset (0dB) meter output (enabled)
TOSLINK input name (TOSLINK) level oset (0dB) clocksource (TOSLINK) s-lock (enabled)
demphasis (auto) meter output (enabled)
ADAT18 input name (ADAT) level oset (0dB) clocksource (ADAT) s-lock (enabled)
demphasis (off ) s/mux (off ) meter output (enabled)
AES DW input name (aes dw) level oset (0dB) clocksource (aes dw) s-lock (enabled) demphasis (auto)
meter output (enabled)
S/PDIF input name (S/PDIF) level oset (0dB) clocksource (S/PDIF) s-lock (enabled) demphasis (auto)
meter output (enabled)
AES1 input name (AES1) level oset (0dB) clocksource (AES1) s-lock (enabled) demphasis (auto)
meter output (enabled)
AES2 input name (AES2) level oset (0dB) clocksource (AES2) s-lock (enabled) demphasis (auto)
meter output (enabled)
USB input name (USB) level oset (0dB) clocksource (internal) s-lock (enabled) demphasis (off)
meter output (enabled)
SPEAKER SETUP
Pressing any of the speaker buttons selects that output for the monitoring path (exactly as it does in
normal mode) and brings up the setup information for that speaker output. The following are the de-
tails of each of the speaker setup parameters.
SPEAKER NAME This parameter allows the user to customize the displayed name for each speaker output.
For this parameter, the control is a little dierent, but again, you will remember how to do this from get-
ting the high score on Asteroids. Or Centipede.
Pressing the encoder once brings up the character cursor. From here, rotate the knob to position the cur-
sor under the character you wish to edit.
Press the encoder again to enter edit. Rotate the knob until the desired character is displayed. Press the
encoder again to enter the desired character and get back to the cursor.
Once all of the desired changes are complete, move the cursor back to the “<” and press the encoder to
initiate the name change.