EasyManua.ls Logo

Grace M905 - Updating ACU Firmware

Grace M905
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Once the reprogramming is com-
plete, the m905 RCU will disconnect/
reconnect itself from the computer.
Open the folder again. A file named
“SUCCESS.TXT should be in the folder.
This is your indication that the firm-
ware update process has completed
successfully.
If the m905 RCU encounters any
problems during the USB upgrade
process, the folder will contain a file
named “ERROR.TXT.
The type of problem encountered is
reported on the Status line in ERROR.
TXT. In this example, a firmware
file for the ACU was accidentally
uploaded as indicated by the “Invalid
Device” error. Should an error occur,
restart the firmware upgrade process.
Disconnect the USB cable from the
RCU and then cycle the power to the
m905.
UPDATING ACU FIRMWARE
TO UPDATE THE FIRMWARE ON THE m905 ACU PERFORM THE FOLLOWING STEPS:
Download the m905 firmware package from the Grace Design Website and unzip it on your computer.
Turn off the m905 and connect your computer via USB to the USB upgrader port on the m905 ACU.
Turn on the m905. The m905 will enter USB upgrader mode instead of communicating with the m905 RCU.
(the m905 RCU will display a communication error.)
Once the m905 initializes it will appear
on your computer as a ‘mass storage class
device with the name m905_ACU.
Open the folder. It will contain a single
file named “READY.TXT. This indicates that
m905 ACU is now ready for the firmware
update. Simply locate the firmware file
that was downloaded (filename starts with
m905_ACU), drag and drop the file to the
folder containing READY.TXT.