Common Procedures
333394H 19
Unclogging Spray Tip
In the event that particles or debris clog the
spray tip, this sprayer is designed with a
reversible spray tip that quickly and easily
clears the particles without disassembling the
sprayer.
1. Perform Pressure Relief Procedure,
page 14.
2. To unclog spray tip, turn Prime
Pump/Spray knob down to Prime Pump
position.
3. Reverse spray tip to UNCLOG position.
4. Dual speed models:
Move speed control switch to HIGH
setting.
5. Variable speed models:
Set speed control to 10.
6. Aim sprayer at waste area, turn Prime
Pump/Spray knob forward to spray
position. Pull trigger to clear clog.
7.
Turn Prime Pump/Spray knob down to
Prime position.
Rotate spray tip back to
SPRAY position. Turn Prime
Pump/Spray knob forward to SPRAY
position, and resume spraying.
8. If spray tip is still clogged, you may have
to repeat steps 2 - 7, or replace with new
spray tip assembly. See Installing
Spray Tips, page 18.