11
306–694
Maintenance
WARNING
T
o reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure
on page 8.
Keep the packing nut/wet–cup (R) half filled with Graco
Throat Seal Liquid (TSL) or compatible solvent, to help
prolong
the packing life. Check
the tightness of the pack
-
ing nut weekly. Adjust the packing nut so it is just tight
enough to prevent leakage; do not overtighten. Always
relieve
the pressure
before adjusting the packing nut.
Each day, check the lubricator and fill as needed, drain
the
air filter
, and clean any fluid line filters. Always
relieve
the
pressure
first.
Check V
alve Adjustment
To
adjust the intake check valve, refer to the separate dis
-
placement
pump manual 307–862.
Shutdown and Care of the Pump
WARNING
T
o reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure
on page 8.
For overnight shutdown relieve the pressure. Always
stop
the pump at the bottom of
the stroke to prevent the
fluid from drying on the exposed displacement rod and
damaging
the throat packings.
Always flush the pump before the fluid dries on the dis-
placement
rod. If you do not flush a circulating system ev
-
ery
day
, be
sure the fluid is circulated frequently enough
to
prevent fluid from drying or settling during shutdowns.
Never
leave water or water–based fluid in the pump over
-
night.
First flush with water or a compatible solvent, then
with
mineral spirits.
Relieve the pressure
after flushing,
but
leave the mineral
spirits in the pump to protect parts
from
corrosion.

Related product manuals