306–694
Technical
Data
Maximum
fluid working pressure
3000 psi (21.0 MPa, 210 bar)
.
. . . . . . . . . . . . . . . . . . . . . . . . .
Air
input pressure operating range
40–100 psi (0.28–0.7 MPa, 2.8–7 bar)
.
. . . . . . . . . . . . . . .
Ratio 30:1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump
cycles per 1 gallon (3.8 liters)
20.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum
recommended pump speed for continuous operation
60 cycles per min
.
. . . . . . . .
Maximum
flow
3 gpm (1
1.34 liter/min)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air
consumption
approx. 34 scfm (0.95 m
/min).
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
at
1 gpm (3.8 liters/min) at 100 psi (0.7 MPa, 7 bar) air pressure
Air inlet
3/4 npt(f)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid
outlet
3/4 npt(f)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight approx.
75 lb (34 kg)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted
parts
See displacement pump manual 307–862
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
500
1000
1500
2000
2500
3000
012345
FLUID
FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
gpm
liters/min
To
find Fluid Outlet Pressure
(bar/psi/MPa) at a specific fluid flow
(lpm/gpm) and operating air pressure (bar/psi/MPa):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
T
o find Pump Air Consumption
(m
/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (bar/psi):
1.
Locate desired flow along bottom of chart.
2. Read
vertical line up to intersection with
selected air consumptio
n
curve
(gray). Follow right to scale to read air consumption.
cycles/min
20
scfm
m
/
min
20
1.120
0.56
psi
bar
MPa
40
psi (0.3 MPa, 3 bar)
air pressure
70 psi (0.49 MPa, 4.9 bar)
air pressure
40 psi (0.3 MPa, 3 bar)
air pressure
70 psi (0.49 MPa, 4.9 bar)
air pressure
KEY:
Fluid Outlet Pressure – Black Curves
Air Consumption – Gray Curves
40
35
3.5
70
7.0
175
17.5
140
14.0
105
10.5
7.6
40
100
100 psi (0.7 MPa, 7 bar)
air pressure
100 psi (0.7 MPa, 7 bar)
air pressure
210
21.0
80
15.2
2.80
1.680
60
2.240
80
19.011.43.8
60
3
2
2
1
1