Loading...
8 308443
Installation
Flange Connections
The fluid inlet and outlet ports are 1” raised face
flanges. Connect 1” flanged plastic pipe to the pump
as follows. You will need:
Torque wrench
Adjustable wrench
One 4.25” diameter, 1/8” thick gasket, with
four 0.62 diameter holes and a 1.15” diameter
center
Four 1/2” x 2.5” bolts
Four 1/2” spring lockwashers
Eight 1/2” flat washers
Four 1/2” nuts.
1. Place a lockwasher and a flat washer on each bolt.
Refer to Fig. 3.
2. Align the holes in the gasket and the pipe flange
with the holes in the pump flange.
3. Lubricate the threads of the four bolts. Install the
bolts through the holes and secure with the wash-
ers and nuts.
4. Hold the nuts with a wrench. Refer to the tighten-
ing sequence in Fig. 3 and torque the bolts to
10 to 15 ft-lb (14 to 20 N-m). Do not over-torque.
Fig. 3
1
04405
KEY
A Flanged plastic pipe
B gasket
C Bolt
D Lockwasher
E Flat washer
F Nut
R 1” fluid inlet flange
S 1” fluid outlet flange
A
B
C
D
E
E
F
S
R
Torque to 10 to 15 ft-lb (14-20 N-m).
Do not over-torque.
1
2
3
4
1
BOLT TIGHTENING SEQUENCE
1
04404B
PTFE
PTFE

Related product manuals