Clean Up
334558D 25
7. While continuing to trigger gun, turn
prime valve down. Then release gun
trigger. Allow flushing fluid to circulate
until fluid comes out of drain tube clear.
8. Raise siphon tube above flushing fluid
and run sprayer for 15 to 30 seconds to
drain fluid. Turn hydraulic valve OFF.
Turn engine OFF or turn electric motor
OFF and unplug.
9. Engage trigger lock. Remove filters
from gun and sprayer, if installed. Clean
and inspect. Reinstall filters.
10. Depending on model, either remove nut
and inlet strainer screen from bottom of
suction tube, or unscrew and remove
inlet strainer. Clean and replace
strainer screen if necessary. Reassem-
ble.
11. If flushing with water, flush again with
mineral spirits, or Pump Armor, to leave
a protective coating to prevent freezing
or corrosion.
12. Wipe sprayer, hose and gun with a rag
soaked in water or mineral spirits.