6 307843
Installation
Mounting the Pump
D 400 and 1200 Series Pumps: Mount the pump
with the accumulators in the top position as shown
in Fig. 1. The accumulators must be in the position
shown or the pump will not prime.
D Be sure the pump is securely bolted to its mounting
and that the mounting can support the weight of the
pump, hoses, and stress caused during operation.
D The outlet manifold can be removed and turned 180
degrees to change the direction of the outlet and
ease installation, as shown in Fig. 3.
General Information
D The installation shown in Fig. 4 is only a guide for
selecting and installing system components. Con-
tact your Graco distributor for assistance in plan-
ning a system to suit your needs.
D See pages 38 through 43 for accessories and kits
available from Graco. Always use Genuine Graco
Parts and Accessories.
D Use a thread sealant compatible with the fluid being
pumped on all male pipe threads. Tighten all con-
nections firmly to avoid air or fluid leaks.
D Reference numbers and letters in parentheses in
the text refer to the figure illustrations.
Fig. 1
accumulators
02321