Appendix G - Communications Gateway Module Installation Kit
108 3A2797ZAA
98
Blue Material Chiller
Zone, temperature
Current Zone Actual Temperature, in 0.1 C
o
units
Read
102
Heater Zones
Enabled Bit Masks
Bit 0 = Red Tank Zone Enabled (1) or Disabled (0).
Bit 1 = Blue Tank Zone Enabled or Disabled.
Bit 2 = Red Inline Heater Enabled or Disabled.
Bit 3 = Blue Inline Heater Enabled or Disabled.
Bit 4 = Red Hose Heater Enabled or Disabled.
Bit 5 – Blue Hose Heater Enabled or Disabled.
Bit 6 = Red Chiller Enabled or Disabled.
Bit 7 = Blue Chiller Enabled or Disabled.
Read
103
Heater Zones On/
Off Bit Masks
Bit 0 = Red Tank Zone Turned ON (1)/ Off (0).
Bit 1 = Blue Tank Zone Turned ON/ Off.
Bit 2 = Red Inline Heater Turned ON/ Off.
Bit 3 = Blue Inline Heater Turned ON/ Off.
Bit 4 = Red Hose Heater Turned ON/ Off.
Bit 5 – Blue Hose Heater Turned ON/ Off.
Bit 6 = Red Chiller Turned ON/ Off.
Bit 7 = Blue Chiller Turned ON/ Off.
Write
104 Read
120
Current Tank Level
Status
Least Significant Byte – Red Tank Level
2
nd
Significant Byte – Blue Tank Level
Level indications/ Byte:
1 = Material is below Low Level sensor.
2 = Material between Low and High Level (2
nd
) sensors.
3 = Tank Full (at 2
nd
sensor, or above).
7 = Material at or above top sensor (“Report xxx High Level in bit
2” feature ON).
Read
121
Tank Filling Control/
Status, Red Tank
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
Write
122 Read
123
Tank Filling Control/
Status, Blue Tank
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
Write
124 Read
130 Ratio, Setpoint
In 0.001:1 units of measure. So for instance, a value of 23680 =
23.680:1. Ratio may be inverted based on the setting of the
“Ratio:” control selection on the System #3 setup screen.
Ratios are either volumetric or weight depending upon the “Flow
Units” Selection on the ADM Advanced #2 setup screen.
Read
132 Ratio, Actual
In 0.001:1 units of measure. So for instance, a value of 23721 =
23.721:1. Ratio may be inverted based on the setting of the
“Ratio:” control selection on the System #3 setup screen. This
data is only valid if HFR or NVH has a Ratio Monitoring option
installed.
Read
Data Exchange
Pointer
Designation
Description Comments, Data Element Descriptions
Read/
Write