Appendix G - Communications Gateway Module Installation Kit
112 3A2797ZAA
Error Number Tables:
The following table documents all the possible error
numbers and codes generated by a HFR or NVH sys-
tem. If no error is present, a 0 will be provided in the
corresponding register (No Active Errors). The Code
column indicates the 4 digit code presented to the user
on the ADM. The following error codes have been
assigned one of the 3 possible levels, documented in
column 4:
• Alarm (A) – Most severe, typically shutting down the
system.
• Deviation (D) – Less severe condition which may or
may not shut down the system.
• Advisory (V) – Simply a warning, which does NOT
shut down a system.
The last column reflects the text description provided to
the user (when HFR/ NVH configured to English) when
the error number is generated.
Item #
Error
Number
Code Level Description
0 0 n/a --- No Active Errors
1 1 T4N1 A
Blue Motor Temp.
Shutdown
2 2 T3N1 V
Blue Motor Temp.
Cutback
3 3 T4H1 A
Blue MCM Oil Temp.
Shutdown
4 4 T3H1 D
Blue MCM Oil Temp.
Cutback
5 5 MBH1 A
Blue MCM Low Oil
Level
6 6 A4H1 A
Blue Motor Over
Current
7 7 A4N1 A
Blue Motor Over
Current
8 8 A4M1 A
Blue Motor Over
Current
9 9 A9C1 A
Blue Motor Over
Current
10 10 T4C1 A
Blue MCM High
Temp.
11 11 V4H0 A
Blue MCM
Overvoltage
12 12 V1H1 A
Blue MCM
Undervoltage
13 13 WBH1 A
Blue Motor Encoder
Fault
14 14 WMH1 D
Blue Motor Controller
Fault
15 15 MBN1 V
Blue Motor Low
Performance
16 16 WKH1 A
Blue Motor High
Speed
17 17 N4A1 D
Blue Pump Failed to
Move
18 18 WSC0 D
Invalid Setpoint
Request
19 19 B9C0 D Small Shot Request
20 20 P4D0 A Pressure Imbalance
21 21 DSC0 A Pumps Not Defined
22 22 D5A1 D
Invalid Learn Mode
Data Blue
23 23 500 D
Invalid Weight Cal.
Data
24 24 D6A1 A
Blue Position Sensor
Fault
25 25 P6A1 A
Red Pressure Sensor
Fault
26 26 P6B2 A
Blue Pressure Sensor
Fault
27 27 D1A1 D
Blue Setpoint Not
Reached
28 28 D4A1 D
Blue Setpoint
Exceeded
29 30 P4A1 A
Red Pressure
Shutdown
30 31 P4B2 A
Blue Pressure
Shutdown
31 32 DFA1 D
Red Pump Not
Parked
32 33 F7D1 D
Blue Pump Failed to
Stall
33 34 WSD0 D
Invalid Gel Timer
Definition
34 35 DDA1 D Red Pump Cavitation
35 36 DDB2 D Blue Pump Cavitation
36 43 WDF1 D
Dispense Valve Open
Problem
37 44 WDF1 A
Dispense Valve Failed
to Close
38 62 WSC0 D
Invalid Setpoint
Request
Item #
Error
Number
Code Level Description