Setup
40 3A2797ZAA
17. Install GX-16 Orifices
a. Close both A side (Red) and B side (Blue) feed
inlet valves on the system. See F
IG. 2 on page
14.
b. Close A side (Red) material return ball valves on
the material tank stand.
c. Follow Pressure Relief Procedure on page 43.
d. Remove plugs from GX-16.
e. Install orifices provided.
18.Pressure check hose
See hose manual. Pressure check for leaks. If no leaks,
wrap hose and electrical connections to protect from
damage.
19.Check hydraulic fluid level
Hydraulic reservoir is filled at the factory. Check fluid
level before operating the first time, and weekly thereaf-
ter. See Technical Data on page 117 for specifications.
FIG. 23: GX-16 Plug Location
ti17747a
Orifice
(A) Side