Appendix B - ADM Setup Screens Overview
58 3A2797ZAA
2. Type the new value then press to accept the
new value.
Calibration Screen, Main
This screen shows calibration information for the sys-
tem and provides access to other calibration screens.
See Calibrate HFR on page 37 for how to use the cali-
bration screens to calibrate the machine.
The date next to each key represents the last time that
calibration was performed.
The “Cal. Min” and “Cal. Max” values are the system
recognized extreme ends of piston travel. See Calibra-
tion Screen, Learn Mode.
Press to go to the Calibration Screen, Learn
Mode screen.
Press to erase the motor control database in the
motor control module.
Calibration Screen, Learn Mode
This screen allows the user to calibrate piston position.
The piston can be moved to the left and right to obtain
the full range of motion. See Calibrate HFR on page 37
for how to use this screen to calibrate the machine.
Press and then to move the pump all the way
to the left.
Press and then to move the pump all the way
to the right.
Press to return to the Calibration Screen, Main.
This saves the new left and right numbers.
Previously saved left
position
Previously saved right
position
Current position