Appendix D - ADM Error Codes
78 3A2797ZAA
CAA2
Comm. Error
Red Hose
Communication error Alarm
Module missing power Check power supply connection
CAA3
Comm. Error
Red Inline
Module not programmed Program the module
CAA6
Comm. Error
Red Blanket
Module bad Replace module
CAA7
Comm. Error
Red Chiller
CAB1
Comm. Error
Blue Inline
CAB4
Comm. Error
Blue Hose
CAB5
Comm. Error
Blue Blanket
CAB8
Comm. Error
Blue Chiller
CAC1
Comm. Error
Motor
CAC2
Comm. Error
MCM
CAC3
Comm. Error
Red Tank
CAC4
Comm. Error
Blue Tank
CAC5
Comm. Error
Mix Head
CAC6
Comm. Error
Mix Head 2
CAC7
Comm. Error
Ratio Monitor
CAC9
Comm. Error
Small
Dispense Kit
CACN
Comm. Error
Gateway
CACP
Comm. Error
DGM
CACR
Comm. Error
Remote
Pendant
CAD1
Comm. Error
Mixer
Voltex Mixer Module is Off line
(HFR Only)
Alarm
CAN cable to Voltex
FCM3 is disconnected.
FCM3 failure.
Reconnect, ensure cable. Verify proper LED
indications on Voltex FCM3.
CUCN
Gateway
Heartbeat
Error
Heartbeat Error Alarm
PLC is not maintaining
heartbeat
Ensure PLC is triggering the heartbeat
Module missing power Check power supply connection
Module not programmed Program the module
Module Bad Replace module
D1A1
Setpoint Not
Reached
The set point was not reached
and the pump was shutdown
Deviation
Material restriction too
high for requested flow
Reduce flow request
D2A1
Setpoint Not
Reached
The set point was not reached Deviation
Pump cannot reach the
requested pressure
Increase restriction in the system
Pump cannot reach the
requested flow
Decrease restriction in the system
Error
Code Error Name Error Description
Error
Type Cause Solution