Spraying Techniques
309205R 13
Swivel Tube Adjustment
The adjustable swivel tube allows the HVLP-Turbine
Gun to be held in any position while spraying. Fig. 16.
To adjust the position of the tube in the cup:
1 Loose nut (A) with a wrench.
2 Rotate cup to the desired spray position.
3 Retighten nut (A) with a wrench.
F
IG. 16
Converting the HVLP Turbine
Cup Feed Gun to Pressure Feed
(Parts 22).
1 Using a pliers, remove air pressure tube (30b) from
air stem (31).
2 Hold adapter fitting (28) with wrench. Remove cup
assembly.
3 Remove air stem (31) from gun body (1).
4 Apply medium strength thread locker to set screw
(36) and assemble into gun body (1).
Note: To convert from pressure feed cup to cup feed,
reverse these instructions.
A
Cup
A
Cup
Swivel tube positioned for spraying UPSwivel tube positioned for spraying DOWN
TI0804
Swivel tube