Gun Placement
16 311017A
Trigger Sensor Adjustment
No fluid spray No spray icon
1 Start sprayer engine. DTS
displays psi only. Engage
trigger. Spray icon
should appear
simultaneously with start
of fluid spray.
2 Turn screw in handle
clockwise if spray icon
appears before fluid spray
starts.
3 Turn screw in handle
counterclockwise if fluid
spray starts before spray
icon appears.
4 Continue adjusting screw
in handle until timing of
spray icon and fluid spray
are synchronized.
WLD
WLF
WLE
WLD