Troubleshooting
Problem
Cause Solution
Faulty FTS connections. Verify that all FTS connections are
snug and that pins of connectors
are clean. Unplug and re-plug
FTS wires along length of hose,
cleanin g off a ny debris .
FTS not installed correctl y. FTS should be installed close to
end of hose in same environment
as gun. Verify FTS installation,
see Repa ir Fluid Temperatu re
Sensor (FTS), page 66.
Erratic hose temperature.
Missing or damaged insulation
around FTS, causing the hose
heat to be ON constantly.
Makesurethehosebundle
has adequate insulation evenly
covering the entire length and
connection joints.
FTS failed. Check FTS, see Repair Fluid
Temperature Sensor (FTS), page
66.
FTS not installed correctl y. FTS should be installed close to
end of hose in same environment
as gun. Verify FTS installation,
see Repa ir Fluid Temperatu re
Sensor (FTS), page 66.
Loose hose ele ctrical connections.
Check connections. Repair as
necessary.
Circuit breakers tripped. Reset breakers (CB01 ), see
Repair Circuit Breaker Module,
page 55.
Hose zone not turned on. Turn on hose heat zone.
Hose does not heat.
A and B temperature setpoints too
low.
Check. Increase if necessary.