Technical Specifications
Technical Specifications
Reactor 2 E-30 and E-XP2 Proportioning System
U.S.
Metric
Maximum Fluid Working Pressure
E-30 2000 psi 14 MPa, 140 bar
E-XP2 3500 psi 24.1 MPa, 241 bar
Maximum Fluid Temperature
E-30
190°F 88°C
E-XP2
190°F 88°C
Maximum Flow Rate
E-30 30 lb/min 13.5 kg/min
E-XP2 2 gpm 7.6 lpm
Maximum Inlet Temperature
E-30
150°F 66°C
E-XP2
150°F 66°C
Maximum Inlet Fluid Pressure
E-30 300 psi 2.1 MPa, 21 bar
E-XP2 300 psi 2.1 MPa, 21 bar
Maximum Heated Hose Length
Length
310 ft
94 m
Output per Cycle
ISO and RES
E-30 0.0272 gal. 0.1034 l iter
E-XP 2 0.0203 gal. 0.0771 l iter
Operatin g Ambie nt Temper a t ure Range
Temperature
20° to 120°F -7° to 49°C
Line Voltage Requirement
Nominal 200–240 VAC, 1 Phase,
50/60 Hz
195–265 VAC
Nominal 200–240 VAC, 3 phase,
DELTA, 50/60 Hz
195–265 VAC
Nominal 350–415 VAC, 3 phase,
WYE, 50/60 Hz
340–455 VAC
Heater Power
(at 230 VAC rated voltage)
E-30 10 kW 10,200 Watts
E-30, 15 kW 15,300 Watts
E-XP2 15 kW 15,300 Watts
98 333024F