Electro-pneumatic Control Panel Display Screens
Material Recipe Timers Screen
Icon/Field Description
Press to complete the fields of this recipe with the values assigned to another
recipe. After copying, individual fields can be modified to differentiate this recipe
from the one copied. The copied values will overwrite any defined values in this
recipe.
Prime Time
Lengthoftime,inseconds,toattempttoachieveaprimeofthepumpwiththe
product in the tote. The pump will operate at the slow speed until the amount of
time specified by this field has elapsed. The pump will then operate at the fast
speed.
Empty Time When the ram assembly reaches the empty sensor, the pump will switch to the
slow pump speed. The pump will then operate for the amount of time entered in
this field. Once this time has elapsed, the pump will stop or raise if auto raise is
checked.
Seal Deflate Time Length of time, in seconds, to deflate the ram plate seal.
Air Assist Time
Length of time, in seconds, to apply blowoff air.
Save the current values displayed. If this screen is exited without saving, any
changes made to the screen are lost.
Return to the recipe list screen. If this screen is exited without saving, any changes
made to the screen are lost.
40 3A5416C