Electro-pneumatic Control Panel Display Screens
Feedback Cont
rol
To reduce the risk of injury due to electric shock, remove power to the control panel before entering the
control panel to make connections for measurement devices.
Selecting scale feedback Selecting pulse feedback
Icon/Field Description
Feedback Type
Select feedback type:
• None: No feedback enabled
• Pulse Meter (Volume): A pulse meter measuring volume dispensed is connected
• Pulse Meter (Mass): A pulse meter measuring mass dispensed is connected
• Scale (Positive): A scale measuring weight is connected; weight is increasing as
material is dispensed.
• Scale Negative: A scale measuring weight is connected; weight is decreasing as
material is dispensed. This input is used if the STU system is mounted on a scale.
K-Factor
This field appears if a pulse meter type input is selected and a pulse meter is
connected to CM8281-12 (20 kHz max). Set the unit value a single pulse represents.
Max* This field appears if a scale type input is selected and a scale with 4 - 20 mA output
is connected to CM8281-14(+) and CM8281-16(-). Set the weight associated with
the maximum signal input in this field.
Min* This field appears if a scale type input is selected and a scale with 4 - 20 mA output
is connected to CM8281-14(+) and CM8281-16(-). Set the weight associated with
the minimum signal input in this field.