Cleanup
3A3529C 25
18. Stop triggering gun. Engage the trigger
lock.
19. Turn Prime/Spray valve down to
PRIME position.
20. Turn ON/OFF switch to OFF position.
Cleaning InstaClean
™
Fluid Filter (ProLTS only)
The InstaClean Filter prevents particles from
entering paint hose. After each use, remove
and clean it to ensure peak performance.
1. Perform Pressure Relief Procedure,
page 13.
2. Disconnect airless spray hose (A) from
sprayer.
3. Unscrew outlet valve (B).
4. Remove InstaClean Filter (C).
5. Check InstaClean Filter (C) for debris. If
needed, clean filter with water or flushing
fluid and a soft brush.
a. Install closed (square) end of
InstaClean Filter (C) in sprayer.
b. Screw outlet valve (B) into sprayer.
6. Tighten outlet valve and reconnect hose
(A) to sprayer. Use two wrench to tighten
securely.
Clean the Gun
1. Clean gun filter (A) with water or flushing
fluid and a brush every time you flush the
system. Replace gun filter if damaged.
2. Remove spray tip and tip guard and
clean with water or flushing fluid and a
brush.
3. Wipe paint off outside of gun using a soft
cloth moistened with water or flushing
fluid.
ti27120a
27179a
ti27122a
ti27494a