Settings for running cycle
Push on and buttons at the same time in more than 6 sec. and the menu item [ C ] appears in the
display.
With and buttons it’s possible to look through the main menu item [ C ], [ F ] and [ d ]. Push on
button to enter the submenu from the main menu items.
With and buttons it’s possible to look through the submenus menu items. Push on button to enter
the desired menu item and adjust the setting with and buttons.
To confirm the new setting, push button. Leave the submenu and main menu item with the button..
Menu access P+3
Compressor setup C C1 [° K] Differential for compressor cut-in and cut-out.
C2 [° C] Highest allowed temperature limit for the cabinet.
C3 [° C] Lowest allowed temperature limit for the cabinet.
C4 [min] Forced pause time for compressor between cut-out and cut-in.
C5 Number of condenser sensors connected.
C6 [min] Compressor stop by open door.
C7 [° K] Soft differential for cool/heat cut-out (kelvin)
C8 [° C] Setpoint for condenser fan
C9 [° K] Cut-out differential for condenser fan (kelvin)
Evaporator fan F F1 [° C] Temperature allowing the evaporator fan to start after defrosting.
F2 [min.] Pause time of evaporator fan, while the compressor is stopped.
F3 [sek.] Running time of evaporator fan, while the compressor is stopped.
F4 [° K] Stop temp. of LT compressor i cascade evaporator (celcius)
Display presentation D D1 Number of defrosts / 24h
D2 [° C] Defrost stop temperature measured at the evaporator.
D3 On/off Activation of defrost by start-up sequence [1=on / 0=off].
D4 [min.] Maximum defrosting time.
D5 Selection between automatic- [1], air- [2] or electric defrosting [3].
D6 [min.] Dripping time after defrosting
D7 [° C] Temperature limit deciding the defrosting method, when d5 = [1]
D8 [° C] Evaporator temperature starting an extra defrosting cycle.