765041642 4
When servicing the product.
Make sure the appliance is switched off at the socket before service is performed on electrical
parts. It is not sufficient to switch off the cabinet by the START/STOP key as there will still be
voltage to some electrical parts of the cabinet.
Start-up sequence
When the product switches ON, the software is loaded into the MPC-46.
The display shows multiple informations, see below:
Text Display
Second0‐3:
Softwareisloaded
intoMPC‐46on
start‐up
Allsegmentslightupwhite.Control,iseverythingok?
Thedisplayhasrecognizedversion3.0andawaitsmoreinformation….
Approx.3rdsecond
and3‐4seconds
forward:
NowtheMaxidisplayrecognizesprogrammevariantF3+version3.0.
Thedisplayrecognizesthattheproductisequippedwithone
compressor.
Approx.7thsecond
and3‐4seconds
forward:
Thedisplayrecognizeswhichcontrollampsareneededaccordingto
theprogrammevariantF3+,andtheappropriatelampsarelit.The
versionnumberisdisplayed.
Approx.10th
secondand3‐4
secondsforward:
Allcontrollampsareturnedoff,exceptthecompressorlamp.The
largedisplayisdisplayedreadyforuse.