765041982 Rev. 000 30
"Test Relay" Manual coupling of relays for testing
Parameter Description Setting range
TEr Test Relay
TC Test Compressor 1 + condenser fan ON ("on") - OFF ("TC")
TF Test Evaporator fan ON ("on") - OFF ("TF")
Td Test Defrost heater ON ("on") - OFF ("Td")
TL Test Light ON ("on") - OFF ("TL")
tC2 Test Compressor 2 ON ("on") - OFF ("tC2")
TdP Test Display and Piezo buzzer,
then display of software version at the
secondary diasplay.
ON (Start)
….
Sensor display
Sensor Description
P - A Temperature sensor A ( room sensor )
P - b Temperature sensor B ( evaporator sensor)
P - C Temperature sensor C ( condenser sensor 1 )
P - d
Temperature sensor D (condenser sensor 2 )
P - E Temperature sensor E ( extra sensor )
Sensor defective or not connected
