HT813 Administration Guide
Version 1.0.1.2
NTP Server
Defines the URL or IP address of the NTP server. The ATA may obtain the date
and time from the server. The default setting is “pool.ntp.org”.
Allow DHCP Option 42 to
override NTP server
Defines whether DHCP Option 42 should override NTP server or not. When
enabled, DHCP Option 42 will override the NTP server if it’s set up on the LAN.
The default setting is Yes.
DHCP Option 17 Enterprise
Number
This option contains vendor-specific option data, much like DHCPv4 option 43.
There is an extra difference in that in DHCPv6, this option carries a vendor ID
as well, which allows for data from multiple vendors to be provided to the
device.
Default is 3561.
Syslog Server
URL or IP address of syslog server.
Syslog Level
Select the HT813 to report the log level. Default is NONE. The level is one of
EXTRA DEBUG, DEBUG, INFO, WARNING or ERROR. Syslog messages are
sent based on the following events:
1. product model/version on boot up (INFO level)
2. NAT related info (INFO level)
3. sent or received SIP message (DEBUG level)
4. SIP message summary (INFO level)
5. inbound and outbound calls (INFO level)
6. registration status change (INFO level)
7. negotiated codec (INFO level)
8. Ethernet link up (INFO level)
9. SLIC chip exception (WARNING and ERROR levels)
10. memory exception (ERROR level)
11. extra syslog style (EXTRA DEBUG level)
Send SIP Log
Configures whether the SIP log will be included in the syslog messages.
The default setting is No.
Automatic Reboot
Default is No. When “Yes, reboot every day at houror “Yes, reboot every week
at dayor “Yes, reboot every month at day” is checked, user can specify “Hour
of the day (0-23)” or “Day of the week (0-6) or “Day of the month (0-30)”.
Default time is Monday 1AM.
https://arttel.ru/
https://arttel.ru/shop/voip-shlyuzy/grandstream-ht-813

Table of Contents

Other manuals for Grandstream Networks HT813

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks HT813 and is the answer not in the manual?

Grandstream Networks HT813 Specifications

General IconGeneral
BrandGrandstream Networks
ModelHT813
CategoryGateway
LanguageEnglish

Related product manuals