Important Note
For use with Kerosene* only.
After installing the boiler leave these
instructions with the User.
This appliance is deemed a controlled
service and specific regional statutory
requirements may be applicable.
*Operation on Bio-fuel
All Grant Vortex Eco condensing boilers,
manufactured since May 2011, are
suitable for operation on both standard
kerosene (Class C2 to BS2869) and also
bio-kerosene – up to a 30% blend (B30K).
All burner settings and nozzle sizes (as
detailed in Section 2.3 of this manual) are
correct for both standard kerosene and
bio-kerosene (B30K).
In order to operate this boiler on bio-
kerosene it will be necessary to take
the following actions:
Use a bio-kerosene (B30K
compatible flexible oil line in place of
the oil line supplied with this boiler.
Have your oil storage tank and oil
supply line (including all pipework,
sight gauges, filters, isolating valves,
fire valves, ed-aeration devices, etc.)
checked for their compatibility with
bio-kerosene (B30K).
Where necessary some, or all, of
these items may have to be replaced
with a bio-kerosene compatible
alternative.
Check the suitability of the flue
system with Grant UK.
Use only bio-kerosene (B30K) that
conforms to OPS24.
IMPORTANT
Under no circumstances should the boiler
be used with bio-kerosene without the
above actions being taken first.
GRANT ENGINEERING (UK) LIMITED
Hopton House, Hopton Industrial Estate, Devizes
Wiltshire SN10 2EU
Tel: +44 (0)1380 736920 Fax: +44 (0)1380 736991
Email: info@grantuk.com www.grantuk.com
This manual is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances are
changed in the interests of continued product improvement.
All good sold are subject to our official Conditions of Sale, a copy of which may be obtained on application.
© Grant Engineering (UK) Limited 2015. No part of this manual may be reproduced by any means without prior written consent.
Date:______________________________
Commissioning Engineer:_____________________________________________________
Tel. No:____________________________
Boiler model:_______________________ Boiler output:________________ kW
Fuel type: Kerosene / Bio-Kerosene
Nozzle size:________________________ Pump pressure:_____________________
Air setting:_________________________ Flue gas % CO2:____________________
Net flue gas temp:___________________ Smoke No:_________________________
System flushed: yes / no Corrosion inhibitor added: yes / no
Antifreeze added: yes / no
For Sealed systems only:
Expansion vessel size:______________________ litres
Expansion vessel charge pressure:___________ bar
Sealed system fill pressure (cold):____________ bar
Service Log
It is recommended that the boiler should be regularly serviced, at least once a year, and
the details entered in the Boiler Handbook by the service engineer.
Declaration of Conformity
We declare that the Grant VORTEX range of Oil Boilers equipped with Riello RDB
burners approved to EN 267: 1999 satisfy the requirements of the following European
Directives:
1. 89/336/EEC - Electromagnetic Compatibility Directive
Referred to the generic standards EN 55014: 1993, EN 50082: 1: 1992
2. 73/23/EEC - Electrical Equipment Safety Regulations Directive
Referred to the generic standard NO: 3260: The Electrical Equipment (Safety)
Regulations: 1994
3. 92/42/EEC - Hot Water Boiler Efficiency Directive
Referred to the generic standard The Boiler (Efficiency) (Amendment) Regulations
1994 (SI 1994/3083)