3−10
CHAPTER 3 Settings and Measurement
(9) REVIEW
This key is used to replay captured data.
•DuringFreeRunning,replayscaptureddata.
The screen used to specify the data replay source file appears; specify the file you want to
replay.
•Whilecapturingdata,recentlycaptureddataisreplayedintwowindows.
(10) DISPLAY
This key is used to switch the window mode.
You can switch the window mode during Free Running (when capturing is stopped) and Capturing.
Pressing this key switches the window display as follows:
<Waveform + Digital Screen>
Displays the waveform and the digital values.
The setting can be changed using the SPAN/TRACE/POSITION
keys.
<Expanded Waveform screen>
Displays only the waveform expanded in full screen mode.
<Digital + Calculation Display screen>
Displays digital values and two calculation results in large letters.
The calculation settings can be made using the Data menu.
* Refer to page 3-27 for details.
- Use the
FAST FORWARD keys to change the display mode.
The calculation results are displayed only in All Mode.
* Refer to page 3-9 for details on All Mode.