◆ The out voltage setup is lower than
charging/discharging battery or the number of cells
is improperly selected
◆ The temperature sensor is plugged in
“backwards,” positive to negative or there is a
fault in the sensor
◆ The battery temperature is too low the be charged
◆ The battery temperature is higher than the preset
temperature
◆ The charger’s internal temperature is too high
◆ Balancer cell voltage is too high
◆ Balancer cell voltage is too low
◆ Threre is a fault in the default calibration date
or charger’s internal circuit
◆ Temperature sensor is disconnected
◆ The preset number of cells and the detected
number of cells are different
◆ The operating current is much higher at MISC
MOTOR function
◆ The balance connector is disconnected
◆ The out voltage setup is lower than
charging/discharging battery or the number of cells
is improperly selected
◆ The preset number of cells and the number of cells
of CH1, CH2 are not matched at Charge/discharge
and Sync mode
Low Output-Volt BLC Volt Low
High Output-Volt
Calibration
Internal Temp.
Motor Current
Temp. Sensor No Sensor
BLC Volt High
Balancer Port
Bat.Temp Too High
Bat.Temp Too Low Connection
Sync. Command
Output voltage is lower
than the selected cells
or voltages.
Pls select proper cells
or voltages.
Balancer cell voltage is
too low !
Low cell is [0]
Output voltage is higher
than the selected cells
or voltages.
Pls select proper cells
or voltages.
Either calibration data or
internal circuit might
have been damaged.
Internal temp is too hot!
Contact Hobby Services
if this message appears
often.
Pls reconnect the moto
rand restart !
A temperature sensor is
connected in reverse or
is defective.
A temp-sensor is not
connected to the port.
Pls connect the sensor
to the port then restart!
Balancer cell voltage is
too high !
Over cell is [0]
BLC Port is opened.
Pls check the BLC port.
Battery temp is too high
to be operated !
Battery temp is too low
to be operated !
Selected cells and
cells connected to the
balancing port are
different !
Pls recheck and restart!
Sync order failed.
Error occured in the
counterpart channel !

Other manuals for GRAUPNER Polaron EX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GRAUPNER Polaron EX and is the answer not in the manual?

GRAUPNER Polaron EX Specifications

General IconGeneral
BrandGRAUPNER
ModelPolaron EX
CategoryBattery Charger
LanguageEnglish

Related product manuals