16
Draining jet
1. Install the draining jet under the
bottom panel
2. Connect with a water pipe to
drain out the water.
Note: Lift the heat pump to install
the jet. Never overturn the heat
pump, it could damage the
compressor.
Water Inlet & outlet junction
1. Install the two joints like the
picture shows
2. Screw them onto the water Inlet
& outlet junction
Cable wiring
1. Open the cover of the electric
box
2. Fix the power supply wire on
joints L N E
Water pump wiring (Dry contact)
1. Open the cover of the electric
box
2. With the connector 1 and 2 you
can pilot the water filtration through
the timer of the filtration (dry
contact)