208
DC Inverter Multi
VRF Service Manual
Removal and Assembly of 4-way valve
Remark: Before removing the 4-way valve, make sure that there is no refrigerant inside the pipe system and that the power has been cut off.
Step Illustration Handling Instruction
1. Loosen the left
wire xer of the
left electric box and
the xing screws
loosen wire fixer
● Remove the left and right front panels.
● Loosen the wire xer
of the electric box.
● Loosen the xing screws
of the left electric box.
2. Remove the
left electric box
● Put a support of suitable height
in front of the left electric box.
● Take off the electric box and lay
its front part on the support.
3. Remove 4-way
valve parts
4-way valve parts
● Loosen the 4-way valve parts.
● Remove the 4-way valve parts.
4. Remove 4-way valve
Solder the spots
● Heat the four nozzles of the 4-way valve
by gad welding. Remove the 4-way valve
● Before solder off the 4-way valve,
record the direction of 4-way valve and
installting position of each nozzle.
Note: do not burn the other
parts during soldering.
5. Remove 4-way
valve from the pipe
● Remove 4-way valve from the pipeline.
6. Mount 4-way valve
● Mount a new 4-way valve
in the right position.
● Conenc the new 4-way
valve to the pipe.
● Wrap the 4-way valve with
wet cloth in case of burnt gliding
block and inow of water.
●Charge nitrogen for welding,
whose pressure is 0.5±0.1kgf/
c (relative pressure).