Service Manual
5. Electrical Part
5.1 Wiring Diagram
● Indoor Unit
● Instruction
Symbol Symbol Color Symbol Symbol Color Symbol Name
WH White GN Green CAP Jumper cap
YE Yellow BN Brown COMP Compressor
RD Red BU Blue Grounding wire
YEGN Yellow/Green BK Black / /
VT Violet OG Orange / /
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
T-SENSOR
TEMP.
SENSOR
TEMP.
SENSOR
RT1
ROOM
TUBE
STEPPING
DISPLAY
PRINTED CIRCUIT BOARD
RECEIVER AND
DISPLAY BOARD
CABLE
CONNECTING
SWING-UD
MOTOR
BLOCK
TERMINAL
AP2
JUMP
CAP
BU
BK
YEGN
EVAPORATOR
PE
XT
2
N(1)
M2
OUTDOOR UNIT
AP1
PG
GENERATOR
COLD PLASMA
FAN MOTOR
M1
RD BU
HEALTH-N
HEALTH-L
PGF
DISP1
DISP2
3
BN
YEGN
RT2
N1
COM-OUT
L
BU
BK
BN
L
L
WIFI MODULE
AP3
(COM-MANUAL)
WIFI
θ
θ
6363222005

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH09QB-K3DNC2G and is the answer not in the manual?

Gree GWH09QB-K3DNC2G Specifications

General IconGeneral
BrandGree
ModelGWH09QB-K3DNC2G
CategoryAir Conditioner
LanguageEnglish

Related product manuals