6
Technical Information
Service Manual
2.2 Operation Characteristic Curve
2.3 Capacity Variation Ratio According to Temperature
Compressor Speed(rps)
Compressor Speed(rps)
Cooling
Heating
Current(A)
Current(A)
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
gnitaeHgnilooC
-22-15 -10-50 510
110
120
130
100
90
80
70
60
50
40
Outdoor temp.(°C)
0
1
2
3
4
5
6
7
8
9
10
020406080100 120
WB19
°C
0
1
2
3
4
5
6
7
8
020406080 100
120
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:4m
Condition
Indoor:DB20°C
Indoor air flow:
High
Pipe length:4m
Condition
Indoor:DB 27°C
Indoor air flow: Super High
Pipe length:4m
Voltage:230V
Condition
Indoor:DB 20°C
Indoor air flow: Super High
Pipe length:4m
Voltage:230V

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH09QB-K3DNC2G and is the answer not in the manual?

Gree GWH09QB-K3DNC2G Specifications

General IconGeneral
BrandGree
ModelGWH09QB-K3DNC2G
CategoryAir Conditioner
LanguageEnglish

Related product manuals