60
Installation and Maintenance
Service Manual
No.
Malfunction 
Name
 Display Method of Indoor Unit
A/C Status Possible Causes Countermeasures
Display 
of dual-
8 nixie 
tube
Indicator Display 
(during blinking, ON 
0.5s and OFF 0.5s)
Operation 
Indicator 
Heat 
Indicator 
1
High pressure 
protection 
E1
Flash 
once 
every 3s
During cooling and drying 
operation, compressor and 
outdoor fan stop while indoor 
fan operates. During heating 
operation, all loads stop.
Refrigerant is 
superabundant;
1. Reduce refrigerant 
volume;
Poor heat-
exchanging (including 
heat exchanger is 
dirty and radiating 
environment is not 
good);
2. Clean the heat 
exchanger; improve 
radiating environment 
of unit;
Ambient temperature 
is too high;
3. Reduce load
Poor connection of 
LPP;
4. After de-energization, 
reinsert LPP terminal 
tightly; 
Pressure switch is 
damaged;
5. Replace pressure 
switch;
Hardware malfunction 
of outdoor units main 
board;
6. Replace outdoor 
units main board; 
2
Freeze 
protection
E2
Flash 
twice 
every 3s
During cooling and drying 
operation, compressor and 
outdoor fan stop while indoor 
fan operates. During heating 
operation, all loads stop.
Poor air return of 
indoor unit;
1. Check whether indoor 
units horizontal louver 
can close normally; 
Rotation speed 
of indoor fan is 
abnormal; 
2. Replace indoor units 
main board→ replace 
indoor fan
Evaporator is dirty;
3. Clean evaporator of 
indoor unit; 
9. Maintenance
9.1 Error Code List