81
Installation and Maintenance
Service Manual
6. PFC (correction for power factor) malfunction (outdoor unit malfunction
Main detection points:
● 
Check if power plug is connected well with the socket?
● 
Check if the reactor of outdoor unit is damaged?
Malfunction diagnosis process:
(11) PFC (correction for power factor) malfunction (outdoor unit malfunction)
Main detection points:
ƽ
Check if power plug is connected well with the socket
ƽ
Check if the reactor of outdoor unit is damaged?
Malfunction diagnosis process:
 
Y
Y
N
N
N
N
Y
N
N
start
If power plug is connected 
well with the socket
Connect the plug correctly
Check the connection wire 
between reactor mainboard 
and situation of connection
If there is short circuit or the 
connection wire is loose?
Reconnect the wire or 
replace the connection 
wire according to the 
wiring diagram.
Check the surface of reactor coil
If it is damaged?
Replace the reactor
Power on and 
restart the unit
Power on and 
restart the unit
Replace outdoor 
mainboard AP1
End
Is the malfunction 
    eliminated?
Is the malfunction 
    eliminated?
Is the malfunction 
    eliminated?