EasyManua.ls Logo

Gree MULTI18HP230V1A

Gree MULTI18HP230V1A
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
119
Disassembly of Outdoor Unit
36,000 btuh Warning - Wait 10 minutes aer power is disconnected before starting disassembly.
7. Remove outer case
Remove the screws holding the outer case and motor support,
middle isolation sheet and chassis, pull the outer case slightly up-
ward, loosen clasps between outer case and right side panel, then
re3move outer case.
8. Remove electric box assy
Remove the ground wire screw on the electric box assy, then re-
move the grounding wire. Disconnect the wiring terminals of all
components that are connected to the electrical box for removal.
Remove the wire from inside the wiring groove.
9. Remove blade, motor, reactor & motor support
Remove the screws holding the axial fan blade, then remove
the blade. Remove the screws holding the motor support to the
chassis, then remove the support. Remove the screws holding the
motor and reactor, then remove each component.
10. Remove 4-way valve
Remove all refrigerant from unit. Unsolder the tubing connect-
ing the compressor, liquid separator, then condenser assembly.
Remove the 4-way valve assembly.
11. Remove valve support
Unsolder all joints on valve support, then remove.
Note: Protect the valves by wrapping in wet cloth.
12. Remove connection pipe sub-assy
Unsolder all joints on pipe sub-assy., then remove.
Outer case
Electric box assy
Reactor
Motor
Blade
Pipe sub-assy
Valve support
4-way valve
Support