AIR-TO-WATERHEATPUMP MAINTENANCE
107
¾ Drive Failure Code
Item
Display on Nixie
Tube of Outdoor
Unit
Display on
Wired Controller
Remarks
Reset of Drive
System
P0 E5
Startup Failure of
Compressor
Lc E5
Phase Protection Ld E5
Lock LE E5
Overspeed LF E5
Current protection of
compressor
P5 E5
Communication
failure
P6 E5
Sensor failure of heat
sink
P7 E5
Overheat protection
of heat sink
P8 E5
AC contactor
protection
P9 E5
AC current protection
(input side)
PA E5
Current sensor failure Pc E5
Connection
protection of sensor
Pd E5
Temperature drift
protection
PE E5
Ambient sensor
failure of drive plate
PF E5
Overvoltage
protection
PH E5
Under-voltage
protection
PL E5
Abnormality of input
AC voltage
PP E5
Charge circuit failure PU E5
IPM protection H5 E5
Desynchronizing of
motor
H7 E5
Inverter Drive
Failure
PFC abnormality Hc E5