AIR-TO-WATER HEAT PUMP CONTROL
29
2)
Press button to select the function code that you want to set.
3) Press button to enter function parameter setting mode. The function
parameter is flashing.
4) Press
button to adjust desired parameter.
5) Press
button to save the desired parameter.
6) Repeat step 2 to 5 to set other function parameter, or press
button or
button to return to the main menu.
The table of user function parameter
Code
Function description
Detail Range
1
Setting interval of defrost
mode
/ 30~60minute(default:50)
2
Setting duration of defrost
mode
/ 1~15minute(default:10)
3
Setting enter temperature of
preventing freezing operation
/ 15(default:3)℃℃
4
Setting exit temperature of preventing
freezing operation
/ 614 (default:12 )℃℃
5
Setting enter temperature of anti-high
temperature operation
/
5560 (default:58 )℃℃
6
Setting exit temperature of anti-high
temperature operation
/
4054 ( default:53 )
7
Setting enter temperature of defrost
operation
/ -100 (default: -4 )
8
Setting exit temperature of defrost
operation
/ 530 (default:15 )℃℃