AIR-TO-WATER HEAT PUMP CONTROL
31
leaving water temperature (solar kit is installed)
Room temperature setting is available when you have selected room temperature
as control target.
Please refer function code 01.
In heating mode, if weather depending mode is activated, you can’t set the room
temperature or outflow water temperature.
In heating mode , there are two Heating operation level:
¾ high temperature cycle
¾ low temperature cycle
Please refer to In function code 19 ;
3) Adjust desired temperature by pressing
button.
Note:
: Increase 1°C or 1°F for each press.
: Decrease 1°C or 1°F for each press.
4) Press
button to save the setting target temperature and return to the main
menu.
The range of the setting temperature (unit:
)
Temperature Mode Temperature range
Outflow water temperatureNO FCU
cool 18~25(default:18)
Outflow water temperatureFCU
cool 7~25(default:7)
high temperature cycle 25~55(default:40)
Outflow water temperature Heat
low temperature cycle 25-45(default:40)
Room temperature cool 18~30(default:20)
Room temperature heat 18~30(default:26)
Sanitary water tank temperature / 40~80(default:50)