U-Match Series DC Inverter Service Manual
114
8. Mount the fan and
tighten the fixing bolts
Mount the fan and use spanner to
tighten the bolts fixing the fan.
9. Mount the water tray
and tighten the screws
Use screwdriver to loosen the screws
fixing the water tray.
Removal and Installation of Drainage Pump
Step
Illustration
Handling Instruction
1. Loosen the screws
fixing the water tray
Use screwdriver to loosen the screws
fixing the water tray.
2. Remove the water tray
Remove the water pump and replace it.
3. Pull out the water outlet
pipe and loosen the
screws fixing the water
pump.
Pull out the water outlet pipe and use
screwdriver to loosen the screws fixing
the water pump.