U-Match Series DC Inverter Service Manual
109
4. Remove compressor
1. Discharge the refrigerant inside the
pipeline and recycle the refrigerant
during discharging;
2. Unsolder the 4-way valve assy
from compressor;
3. Remove the nut fixing compressor;
4.Take away the compressor from
chassis.
5. Assemble unit
Assemble the unit in the reverse
procedures of disassembly.
4.2 Indoor Unit
4.2.1 Duct type
Removal and Assembly of Fan Motor
Remarks: Before removing the fan, make sure to cut off the power firstly.
Step
Illustration
Handling Instruction
1. Unplug the motor cables
Cut off the power supply of indoor
unit. Use screwdriver to remove the
electric box cover and unplug the
motor cables in electric box.
2. Remove the filter
sub-assembly and air inlet
cover board
Remove the filter sub-assembly
from the air inlet frame and use
screwdriver to remove the air inlet
cover board.
3. Remove the screws on
fan sub-assembly.
Remove the screws on fan
sub-assembly.