Wired Controller XK49
8
Figure 3.8 Wrong Connection 1 Figure 3.9 Wrong Connection 2
of Units and Gate Control of Units and Gate Control
2) After wired controller is connected with gate-control device, indoor unit’s on
and off can be controlled with a card: remove the card to turn unit off; insert the card to
restore unit to the condition prior to card removal. The gate control card can control all
indoor units that are linked with the wired controller.
Connection of wired controller and gate control system is as follow:
Figure 3.10 Connection fashion 1 of Wired Controller and Gate Control
3) If two wired controllers are controlling one (or more) indoor unit(s), just connect
one wired controller with the gate control system to control indoor unit’s ON and OFF