Wired Controller XK75 Owner's Manual
11
temperature, press “
∧
” or “
∨
” button to adjust limitation temperature value. After
setting, press MENU button to save the setting.
Note: When save function has been set, auto mode cannot be set.
3.7.8 Auxiliary Heating Function Setting
After entering user function page, press “
∧
” or “
∨
” button to select auxiliary
heating function and press “
<
” or “
>
” button to turn on or turn off this function with auto
saving.
3.7.9 X-fan Function Setting
After entering user function page, press “
∧
” or “
∨
” button to select dry function
option and press “
<
” or “
>
” button to turn on or turn off this function with auto saving.
Note:
①
.
This function is only available in cooling mode and dry mode.
②
.
When this function is on, if the air conditioner is turned off, the indoor fan will
still operate at low speed for a while to blow the residual water inside the air
duct.
3.7.10 Quiet Function Setting
After entering user function page, press “
∧
” or “
∨
” button to select quiet function
and press “
<
” or “
>
” button to turn on or turn off this function with auto saving.
Note: This function is only available in cooling mode, heating mode and auto
mode.
3.7.11 Filter Clean Reminder Setting
After entering user function page, press “
∧
” or “
∨
” button to select clean function
option and press “
<
” or “
>
” button to turn on or turn off this function. Press MENU
button to enter the setting page of filter clean reminder function.
After entering the setting page of filter clean reminder function, press “
∧
” or “
∨
”
button to select pollution level and then press “
<
” or “
>
” button to set pollution level;
press “
∧
” or “
∨
” button to select accumulating time setting and then press “
<
” or “
>
”
button to set required time. After setting, press MENU button to save the setting.
When level 1 is selected, the adjusting range of accumulating operating time is
5500~10000 hours, with 500 hours in each increase or decrease.
When level 2 is selected, the adjusting range of accumulating operating time is
1400~5000 hours, with 400 hours in each increase or decrease.