Ceiling Exhaust Fans 11
®
Typical Installation
The ducting from this fan to the outside of the building has a strong effect on the airflow, noise and energy use of
the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with
smaller ducts than recommended. Insulation around
the ducts can reduce energy loss and inhibit mold
growth. Fans installed with existing ducts may not
achieve their rated airflow.
Rigid metal duct is recommended for optimal fan
performance.
Ensure duct joints and exterior penetrations are
sealed with caulk or other similar material to create
an air-tight path and to minimize building heat loss
and gain and reduce the potential for condensation.
Place/wrap insulation around duct and/or fan to in
order to minimize possible condensation buildup
within the duct, as well as minimize building heat
loss and gain.
*Pu
rchase separately.
INSUL
ATION*
(Place a
round and over Fan Housing.)
ROOF CAP*
(with built-in damper)
FAN HOUSING
POWER CABLE*
ROUND DUCT*
ROUND
ELBOWS*
Seal gaps
around Housing.
Seal duct joints
with tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in damper)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Greenheck SP-AP0511W and is the answer not in the manual?

Greenheck SP-AP0511W Specifications

General IconGeneral
BrandGreenheck
ModelSP-AP0511W
CategoryFan
LanguageEnglish

Related product manuals