Troubleshooting
The Unit Fails to Turn On
1. Verify that the Power Plug is plugged into an operational wall outlet.
2. Ensure that the Power Cord is fully inserted (leaving less than an 1/8”) to the Power Adapter.
3. Ensure that the Power Adapter Plug is fully seated in the receptacle on the back of the unit.
4. Verify the Power Button has been activated on the Control Panel.
5. If the Power Button on the Control Panel fails, use the Power Button on the Remote Control. If the Control Panel fails, contact your distributor of GreenTech Environmental (www.GreenTechEnv.com).
The Unit is Operating in High Mode or Away Mode, but No Noticeable Purication is Being Produced
1. Ensure that the Purication Plate is clean (see “CLEANING: Purication Plate” page 17).
2. The Purication Plate may not be working because it needs to be replaced. Try installing a new Purication Plate.
3. Check the electrical contact arms which touch the plate to ensure that they are making proper contact with the metal weave on the Purication Plate.
4. Ensure the electrical contact arms which touch the plate are clean. Clean them with a soft cloth and rubbing alcohol.
5. Turn the lights off in the room and look through the Front Grille at the Purication Plate. If it is operating properly, it will produce a dim purple glow.
The Purication Plate Generates an Electrical Arc, an Arcing Noise or a Burning Odor
1. This means the Purication Plate is damaged and must be replaced. The unit may or may not display the Replace Plate LCD reminder. To order a replacement, contact your distributor or GreenTech
Environmental (www.GreenTechEnv.com).
The PCO Cell is Not Lighting Up:
1. Ensure the PCO Cell Power Connector is properly seated in the PCO Cell Power Connector Outlet (see “DISASSEMBLY/ASSEMBLY” pages 15-16).
2. If the PCO still fails to operate, it needs to be replaced. Contact your distributor or GreenTech Environmental (www.GreenTechEnv.com).
The Ionization Needle Creates an Electrical Arc:
1. The Ionization Needle needs to be cleaned (see CLEANING: Ionization Needle page 17). Be sure to complete all of the cleaning procedures (see CLEANING page 17)
every 30 days of operation.
The Fan Does Not Operate Properly:
1. Try adjusting the fan speed using the Control Panel or Remote Control.
2. Remove the Front Grille (see “DISASSEMBLY/ASSEMBLY” pages 15-16) to ensure there are no obstructions to the movement of the fan.
3. If the Fan continues to operate improperly or not at all, contact your distributor of GreenTech Environmental (www.GreenTechEnv.com).
The Unit Makes a Rattling Noise When Taken Out of Packaging
1. Remove the back panel of the unit (see DISASSEMBLY/ASSEMBLY” pages 15-16). Check to ensure the two brass Thumb Screws holding the Filter Assembly are in their proper place. If they
are properly installed, remove the Thumb Screws and Filter Assembly (see “DISASSEMBLY/ASSEMBLYpages 15-16) and check the PCO Cell to ensure the two brass Thumb Screws securing the
PCO Cell are installed properly