1110
BALANCING
Balancing must be completed using the Greentek ECO-Touch
®
Programmable Touch Screen Wall Control
ENTERING BALANCING
MODE
In the options menu during
the initial 5 second countdown
sequence, long press on "ECO"
area for 5 seconds to enter
basic balancing mode.
The supply and exhaust fans are
adjusted on high speed only and
the offsets are proportionally
applied to the medium and low
speed automatically.
AUTO MANUAL
OPTIONS
AUTO MANUAL
OPTIONS
NEXT
Supply
manometer
High
High
Low
Low
Exhaust
manometer
STAGE 1
(ADJUST LEVEL OF EXHAUST FAN IN HIGH SPEED):
• In this step, balance exhaust fan and measure airow on the
exhaust air side
• Pressing on "up" or "down" will adjust the fan speed in increments
of 1%.
• Once the desired exhaust airow is reached, press on "next" and
move on to the next stage.
STAGE 2
(BALANCE SUPPLY FAN ONLY IN HIGH SPEED):
• In this step, balance supply fan and measure airow on the supply
air side
• Pressing on "up" or "down" will adjust the fan speed in increments
of 1%.
• Once happy with the outcome, press on "next" to complete
balancing
• The supply and exhaust offset values will be proportionally applied
to low and medium speed as well.
AUTO MANUAL
OPTIONS
NEXT
0 %
ADJUST
AUTO MANUAL
OPTIONS
NEXT
0 %
BALANCE
WALL CONTROLS (CONT'D)
AUXILIARY CONTROL –These controls can be paired with central controls or combined together.
*Maintain polarity between control and HRV
(+ → + ; - → -)
T SERIES FEATURES CONNECTS TO
T4*
• 20- minute timer with LED light
• Boosts system to high speed with the touch of a button
• Up to 5 can be used in one system
• Use in bathroom, kitchen, laundry room
+T
-T
T5* • 20/40/60 minute timer with LED light
• Boosts system to high speed with the touch of a button
• Up to 5 can be used in one system
• Use in bathroom, kitchen, laundry room
RD-1 • Rotary dial Dehumidistat
• Multiple units can be used
• We recommend setting the relative humidity above 80% during the summer
D
D