ELECTRICAL
W A R N I N G
Keep the extension cord clear of the working area. Position the cord so that it will not get caught
on lumber, tools, or other obstructions while you are working with a power tool. Failure to do so
can result in serious personal injury.
W A R N I N G
Check extension cords before each use. If damaged replace immediately. Never use the product
with a damaged cord since touching the damaged area could cause electrical shock resulting in
serious injury.
GROUND FAULT CIRCUIT INTERRUPTER
This unit is equipped with a Ground Fault Circuit Interrupter (GFCI), which guards against the
hazards of ground fault currents. An example of ground fault current is the current that would
, or earth.
GFCI plugs do not protect against short circuits, overloads, or shocks.
**Ampere rating (on product data plate)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Cord Length Wire Size (A.W.G.)
25'
16
16
16
16
14 14
50'
16
16
16
14
14 12
100'
16
16
14
12
10 ---
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge