SPECIFICATIONS
Flow Rate Range: 0.25 to 40 ft/sec ((0.08 to 12.2
m/sec) in most applications
Pipe Size: Any pipe ID from 0.5" to 180"
(12.5mmto4.5m)
Accuracy: ±2% of full scale. Requires solids
or bubbles minimum size of 100
microns, minimum concentration 75
ppm. Repeatability: ±1%, Linearity
±0.5% of full scale
Displays: Flow Rate large, 4-digit LCD in
programmable engineering units
Totalizer/Menu/Status/Signal
Strength 16-digit LCD,
alphanumeric
Calibration: built-in 3-key calibrator, No-drift
transmitter: quartz crystal
frequency reference
Power Input: 100-130VAC, 50/60 Hz, (7.2 W max.)
Optional: 200-260VAC, 50/60 Hz, (7.2 W max.)
Optional: 12VDC or 24VDC, (6.5 W max.)
Power Consumption: 120VAC 0.06 amps (7.2 W); 240VAC 0.03 amps (7.2 W);
24VDC 0.27 amps (6.5 W); 12VDC 0.54 amps (6.5 W)
(Relays Off reduces by 1 W; 4-20mA disconnected reduces by 0.5 W)
Output: Isolated 4-20mA (1000 ohm load max.)
Control Relays: Qty 3, rated 5 amp SPDT, programmable flow alarm and/or proportional pulse
Back Flow Rejection: forces display and outputs to zero with contact closure from remote relay
Enclosure: watertight, dust tight NEMA4X (IP66) fiberglass with a clear shatter-proof face
Electronics Operating Temp: -10° to 140°F (-23° to 60°C)
Sensitivity: adjustable. Damping: adjustable
Electrical Surge Protection: Sensor, 4-20mA output and AC power input
SE3 Doppler Sensor
Minimum Pipe Diameter: 0.5" (12.5 mm) ID,
0.6" (15 mm) OD
Maximum Pipe Diameter: 180" (4.5 m) ID
Operating Temperature: -40° to 200°F (-40°
to 93°C)
Operating Frequency: 640 KHz
Sensor Housing: Stainless Steel with
Epoxy face
Sensor Cable: 20 ft. (6 m) shielded
coaxial pair
(RG174U)
Optional 50 ft (15 m) continuous
Submersion Rating: Withstands accidental submersion pressure up to 10 psi (0.7 Bar)
Hazardous Locations: Rated for sensor and cable installation in
Class I, Div. I,II, Groups C,D,E,F,G
Hazardous locations with optional
Intrinsic Safety Barriers
Page 39
DFM-IV Doppler Flow Meter
Manual Series A.6
ENCLOSURE
7.4 / 188 mm"
6.46 / 164 mm"
10.94"/278mm
10 / 2 5 4 mm"
CONDUIT ENTRY
LOCATION
SIDE VIEW
5.12 / 130 mm"
DFM-IV
Doppler
Flow Meter
SE
3
DOPPLER SENSOR
SIDE VIEW
END
VIEW
1.25"
31.75 mm
1.0"
25.4 mm
0.285 in
7.3 mm OD
20 ft / 6 m
2.25" / 57 mm