This manual provides information for:
OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
PART NUMBER 174839, REV. D (12/17)
MODELS
BPM-15/30/40G(C,A)
& BPP-30/40G(C,A)
Domestic
ERGONOMIC TILTING
BRAISING PAN
· Stainless Steel
· Manual or Power Tilt
· Gas Heated
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
POST IN A PROMINENT LOCATION
Instructions to be followed in the event user smells
gas. This information shall be obtained by consulting
your local gas supplier. As a minimum, turn o the gas
and call your gas company and your authorized service
agent. Evacuate all personnel from the area.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unied Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to le
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net

Questions and Answers

  • D
    Douglas TuckerAug 15, 2025
    Why won't the burners light on my Groen BPM-15G?
    • B
      Billy CurtisAug 15, 2025
      If the burners on your Groen Commercial Food Equipment aren't lighting, ensure the main gas supply valve is open, meaning the handle is aligned with the gas pipe. Also, confirm the gas supply to the braising pan is at the specified pressure and that the pan body is horizontal. Check the thermostat operation; it should click when the dial is rotated to settings above and below the pan's temperature.
  • K
    Kelly ClarkAug 18, 2025
    What to do if my Groen BPM-15G pan will not heat and the pilot light is out?
    • D
      David LoganAug 18, 2025
      If your Groen Commercial Food Equipment pan isn't heating and the pilot light is out: * Ensure the Combination Gas Control Valve knob is turned ON. * Check the pilot tubing and orifice for any clogging. * Make sure connections from the Powerpile generator to the Pilotstat power unit and Powerpile operator are clean and secure. * Verify the open and closed circuit output voltages of the generator are within the acceptable range using the charts in the manual for the W720 Systems Tester. * If a meter isn't available, try replacing the generator.
  • S
    Sherry RuizAug 22, 2025
    Why does my Groen Commercial Food Equipment pan keep heating after reaching temperature?
    • D
      dhessAug 22, 2025
      If your Groen Commercial Food Equipment pan continues to heat after reaching the desired temperature, check the thermostat dial setting and ensure it's properly calibrated. Also, verify the thermostat operation; it should click when the dial is rotated to settings above and below the pan's temperature.
  • Q
    qbarreraAug 25, 2025
    What to do if my Groen BPM-15G pan stops heating too soon?
    • L
      leahleonAug 26, 2025
      If your Groen Commercial Food Equipment pan stops heating before reaching the desired temperature, first check the thermostat dial setting. Also, ensure the thermostat is properly calibrated. Finally, check the thermostat operation; it should click when the dial is rotated to settings above and below the temperature of the pan.
  • R
    Roberta HoweAug 28, 2025
    Why does the pilot flame go out on my Groen Commercial Food Equipment when I release the knob?
    • J
      Joseph KnoxAug 28, 2025
      If the pilot flame on your Groen Commercial Food Equipment goes out when the Combination Control knob is released, you should check the pilot gas adjustment. Also, ensure the connections from the Powerpile generator to the Pilotstat power unit and Powerpile operator are clean and secure. Check if the open and closed circuit output voltages of the generator are in the acceptable range shown by the charts in the manual for the W720 Systems Tester. Check the resistance of the Pilotstat power unit. If you don't have an appropriate meter, replace the generator first, and then the power unit.
  • M
    Michelle ContrerasAug 31, 2025
    How to fix uneven heating in my Groen Commercial Food Equipment pan?
    • T
      Toni ReidAug 31, 2025
      If your Groen Commercial Food Equipment pan heats unevenly, ensure that the pan body is horizontal. Also, make sure that the pan is preheated properly in accordance with the instructions in the Operation section of this manual.
  • J
    Jody RojasSep 4, 2025
    Why won't my Groen Commercial Food Equipment pan tilt?
    • P
      psimmonsSep 4, 2025
      If your Groen Commercial Food Equipment pan will not tilt, first ensure that the electrical power supply is on. If it still doesn't tilt, check for an overheated actuator motor and wait 15 minutes for it to cool down before attempting to operate the power tilt again.
  • D
    David SmithSep 7, 2025
    What to do if my Groen Commercial Food Equipment pan won't heat but the pilot light is on?
    • B
      Brittany GarnerSep 7, 2025
      If your Groen Commercial Food Equipment pan will not heat, but the pilot light is burning, ensure that the secondary thermostat switch is closed.
  • N
    Noah MosleySep 12, 2025
    Why is the pan hard to tilt on my Groen BPM-15G Commercial Food Equipment?
    • A
      Adam TuckerSep 12, 2025
      If the pan on your Groen Commercial Food Equipment is hard to tilt, check the gears for foreign materials, ensure proper lubrication, and verify alignment. Also, inspect the tilt or worm gears for any breakage.